Home News

Humidity Range of Temperature and Humidity Test Chamber

Certification
Good quality Salt Spray Test Chamber for sales
Good quality Salt Spray Test Chamber for sales
Customer Reviews
Thanks a lot for the professional service of Q1-Test team, we are happy to have the temperature test chamber, and it works well until now.

—— Tonny Cruise

Salt spray test chamber was installed last week according to your guide, it is working well now, thank you. we will recommend it to my friends.

—— Robert Antonio

Our 1000L temperature test chamber QTH-1000C works very well after installed and set by Q1-test service guy. Our staff can operate it fluently. Thanks

—— Juan Smith

I'm Online Chat Now
Company News
Humidity Range of Temperature and Humidity Test Chamber
Humidity Range of Temperature and Humidity Test Chamber

 

Humidity Range of Temperature and Humidity Test Chamber

 

1. Humidity range of constant temperature and humidity test chamber

 

We know that the humidity of constant temperature and humidity test chamber is relative, such as 50%RH at 30℃; 85%RH at 85℃, and so on, rather than from the lower limit of high temperature to the lower limit of low temperature with humidity in the entire temperature range, low temperature means no humidity.

 

Some users have lower humidity requirements for programmable constant temperature and humidity test chambers, such as 15%RH or 5%RH low humidity requirements, etc., but few people ask about the humidity range of 0%RH. Because we all know that 0%RH humidity means no humidity requirements.

 

Just as high humidity of 98%RH is better than humidity of 100%RH, because humidity of 100%RH indicates that moisture is saturated, and saturation equals water.

 

2. What is the humidity when the constant temperature and humidity test chamber is set to 0℃?

 

This depends on whether the operator sets the temperature to 0 °C or the humidity to 0% relative humidity (RH).

 

If the set temperature value is 0, that is, there is no humidity, then this type of equipment cannot be used, because humidity cannot be used at temperatures below 5°C.

 

If the humidity is set to zero, there is no humidity. The humidity range of the general constant temperature and humidity environment test equipment is 20% to 98%RH. The so-called relative humidity refers to the relative temperature of the generated humidity. Not all temperatures can have humidity.

 

There is dry or evaporative humidity, such as high temperatures above 90°C, which basically has no humidity. Below the usual humidity of 5°C, humidity is impossible, because at low temperatures, the moisture in the air will frost or freeze, so 0°C humidity is impossible.

 

In fact, it is possible to set the humidity to 0%, but this only sets the humidity display to 0%, indicating that the humidification system of our equipment will not humidify, but it is impossible to require that there is no water molecule in the air, just as unrealistic as using the best dehumidification equipment in the world.

 